| Customization: | Available |
|---|---|
| Membrane Type: | Spiral |
| Type: | RO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Module | Active Membrane Area | Average Permeate | Stable rejection | Min rejection | B rejection |
ft2 (m2 ) | GPD(m³/d) | Rate(%) | Rate(%) | Rate(%) | |
JHMSW8040-400 | 400(37.2) | 7500(28.4) | 99.85 | 99.7 | 93 |
JHM SW8040-440 | 440(41) | 8250(31.2) | 99.8 | 99.7 | 93 |
JHM SW4040 | 85(7.9) | 1900(7.2) | 99.8 | 99.6 | 92 |
JHM SW8040-440 | 440(41) | 8990(34) | 99.8 | 99.7 | 93 |
JHM SW8040LE-400 | 400(37.2 ) | 9000(34.1 ) | 99.8 | 99.5 | 92 |
JHM SW8040-400V | 400(37.2) | 9000(34.1) | 99.8 | 99.5 | 92 |
Test conditions | |
Testing pressure | 800Psi(5.5Mpa) |
Testing solution temperature | 25℃ |
Concentration of testing solution | 32000ppm Nacl,5ppm B. |
pH value of testing solution | 8.0 |
Recovery rate of Single element | 8% |
Operation limits & conditions | |
Max. Working Pressure | 1200psi(8.27Mpa) |
Max. Temperature of Feed water | 45℃ |
Max. Volume of Feed water | 75gpm(17 m3 /h) |
Max. Feed water SDI 15 | 5.0 |
Max. Feed water Turbidity | 1.0NTU |
pH Range of Feed water during Continuous Operation | 2-11 |
pH Range of Feed water during Chemical Cleaning | 1-13 |
Residual Chlorine Concentration of Feed Water | <0.1ppm |
Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) |
Max. Pressure Drop of Single Pressure Vessel with Six elements | 50psi(0.34Mpa) |
Size of Membrane Element: | 1.0 inch = 25.4 mm |
JHM8inch RO Membrane | ||||||||
No. | Model | Permeate Flow RateGPD/M3/d | Effective Area ft2(m2) | Rejection Rate | Test condition | |||
Min. | Stable | Pressure (PSI) | NaCl | Recovery | ||||
(%) | (%) | rate | ||||||
1 | SW8040-400 | 7500/28.4 | 400(37.2) | 99.7 | 99.85 | 800 | 32000 | 8% |
2 | SW8040-440 | 8250/31.2 | 440(41) | 99.7 | 99.85 | 800 | 32000 | 8% |
3 | FR8040-400 | 11000/41.6 | 400(37.2) | 99.4 | 99.7 | 225 | 2000 | 15% |
4 | LP8040-400 | 11000/41.6 | 400(37.2) | 99.4 | 99.7 | 225 | 2000 | 15% |
5 | LP8040-440 | 12650/48 | 440(41) | 99.4 | 99.7 | 225 | 2000 | 15% |
6 | ULP8040-400 | 12100/45.8 | 400(37.2) | 99 | 99.5 | 150 | 1500 | 15% |
7 | ULP8040-440 | 13300/50.3 | 440(41) | 99 | 99.5 | 150 | 1500 | 15% |
8 | XLP8040-400 | 9500/36.0 | 400(37.2) | 98.5 | 99 | 100 | 500 | 15% |
9 | XLP8040-440 | 10500/39.7 | 440(41) | 98.5 | 99 | 100 | 500 | 15% |
JHM 4inch RO Membrane | ||||||||
No. | Model | Permeate Flow RateGPD/(m3/d) | Effective Area ft2(m2) | RejectionRate | Test condition | |||
Min. | Stable | Pressure (PSI) | NaCl | Recovery | ||||
(%) | (%) | rate | ||||||
1 | SW4040 | 1900/7.2 | 85(7.9) | 99.6 | 99.8 | 800 | 32000 | 8% |
2 | FR4040 | 1900/7.2 | 73(7.0) | 99.4 | 99.7 | 225 | 2000 | 15% |
3 | LP4040 | 2600/9.8 | 87(8.0) | 99.4 | 99.7 | 225 | 2000 | 15% |
4 | ULP4040 | 2850/10.8 | 87(8.0) | 99.3 | 99.5 | 150 | 2000 | 15% |
5 | XLP4040 | 2600/9.8 | 93.5(8.7) | 98.5 | 99 | 100 | 500 | 15% |
JHM commercial ro membrane | |||||||||
Model | Type | Permeae flow | Rejection Rate | Membrane Area | Testing Condition (25℃) | ||||
Testing pressure | NaCl | ||||||||
GPD | m3/d | % | ft2 | m2 | psi | Mpa | Mg/L | ||
SW4021 | Commercial SWRO | 750 | 2.8 | 99.5 | 33 | 3.1 | 800 | 5.52 | 32000 |
SW2521 | 270 | 1 | 99.5 | 12 | 1.1 | ||||
SW2540 | 600 | 2.3 | 99.5 | 28 | 2.6 | ||||
ULP4021 | Ultralow pressure elements | 950 | 3.6 | 99 | 36 | 3.3 | 150 | 1.03 | 1500 |
ULP2521 | 300 | 1.13 | 99 | 14 | 1.3 | ||||
ULP2540 | 750 | 2.84 | 99 | 30 | 2.8 | ||||